Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Acta Orthop Traumatol Turc ; 58(1): 68-72, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38525513

RESUMO

Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Zircônio/efeitos adversos , Desenho de Prótese , Prótese do Joelho/efeitos adversos , Polietileno/efeitos adversos , Falha de Prótese
2.
J Dent ; 142: 104832, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211687

RESUMO

OBJECTIVES: The aim of this study was to evaluate the amount of enamel tooth wear induced by different antagonistic ceramic crown materials in the posterior area within a follow-up period up to 24 months in function. A network meta-analysis was performed to assess the effect of the materials on the mean vertical loss (MVL) of the antagonist enamel tooth surface. DATA: Main search terms used in combination: ceramic, dental materials, metal ceramic, tooth wear and dental enamel. SOURCES: An electronic search was conducted in PubMed/Medline, Embase, and Cochrane CENTRAL plus hand-searching. STUDY SELECTION: Eligibility criteria included clinical studies reporting on MVL on antagonist's tooth up to 24 months following the permanent crown placement. From a total of 5697 articles, 7 studies reporting on 261 crowns for 177 subjects with 3 ceramic materials (Lithium disilicate, metal-ceramic, monolithic zirconia) were included. Among all, metal-ceramic and zirconia caused significantly higher enamel tooth wear on antagonist teeth, representing 82.5 µm [54.4; 110.6]) and 40.1 µm [22.2; 58.0]) more MVL than natural teeth group. In contrast, lithium disilicate showed only 5.0 µm [-48.2; 58.1]) more MVL than occurs on opposing natural teeth. CONCLUSIONS: This systematic review demonstrated that prosthodontic ceramic materials produced significantly more antagonist enamel tooth wear than opposing natural enamel tooth wear, and ceramic material type was correlated to the degree of enamel tooth wear. Additional well-conducted, randomized controlled trials with homogeneous specimens are required due to inadequate sample size and number of the clinical studies included in the analyses. CLINICAL SIGNIFICANCE: The amount of wear caused by different restorative materials has a high influence on the antagonistic natural teeth and should therefore be evaluated intensively by the dentist.


Assuntos
Esmalte Dentário , Desgaste dos Dentes , Humanos , Cerâmica/efeitos adversos , Coroas , Porcelana Dentária/efeitos adversos , Desgaste de Restauração Dentária , Teste de Materiais , Metanálise em Rede , Propriedades de Superfície , Desgaste dos Dentes/etiologia , Zircônio/efeitos adversos , Ensaios Clínicos Controlados como Assunto
3.
Pharmacol Biochem Behav ; 212: 173313, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34896416

RESUMO

Environmental factors have been associated with the etiology of autism spectrum disorder ASD in recent times. The involvement of toxic metals in the generation of reactive oxygen species and their epigenetics effects have been implicated in ASD. This systemic review examines the association of toxic metals with autism in children. A systematic literature search was performed in scientific databases such as PubMed, Google scholar, and Scopus. Case-control studies evaluating toxic metal levels in different tissues of ASD children and comparing them to healthy children (control group) were identified. The Newcastle-Ottawa Scale was used to evaluate the risk of bias of the included studies. Six case-control studies with 425 study subjects met our inclusion criteria. A total of four studies indicated higher levels of As, Pb, Hg, Cd, Al, Sn, Sb, Ba, TI, W, and Zr in whole blood, RBC, in whole blood, RBC, and hair samples of children with autism compared with control suggestive of a greater toxic metal exposure (immediate and long-term). Three studies identified significantly higher concentrations of Cd, Pb and Hg in urine and hair samples of autistic children compared to control suggesting decreased excretion and possible high body burden of these metals. The findings from this review demonstrate that high levels of toxic metals are associated with ASD, therefore, critical care is necessary to reduce body burden of these metals in children with ASD as a major therapeutic strategy.


Assuntos
Transtorno do Espectro Autista/induzido quimicamente , Metais/efeitos adversos , Alumínio/efeitos adversos , Antimônio/efeitos adversos , Arsênio/efeitos adversos , Transtorno do Espectro Autista/sangue , Transtorno do Espectro Autista/urina , Cádmio/efeitos adversos , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Chumbo/efeitos adversos , Masculino , Mercúrio/efeitos adversos , Saúde Pública , Espécies Reativas de Oxigênio , Estanho/efeitos adversos , Titânio/efeitos adversos , Zircônio/efeitos adversos
4.
Eur J Oral Sci ; 130(1): e12831, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34674322

RESUMO

Little information is available about enamel wear caused by zirconia brackets, an inadvertent side effect of orthodontic treatment. The purpose of this study was to examine potential enamel damage induced by contact with zirconia brackets. Sliding and impact wear simulations were performed using bovine enamel specimens positioned at a 25° slant to a zirconium ball to determine wear behaviour. Different chewing patterns, tapping and grinding, were simulated. Specimens were profiled using confocal laser scanning microscopy, and the mean maximum depth and surface roughness were measured. Scanning electron microscopy was also performed. The mean maximum depth of wear values differed according to the number of mastication cycles, with a higher number of cycles producing higher depths of wear. The facet wear depth was significantly greater with the tapping pattern than with the grinding pattern. Scanning electron microscopic observation of the wear facets revealed that surface textures at the edges were rougher than those at the centre of all facets. The results of this study indicated that enamel wear was induced by contact with zirconia brackets during the early period of mastication, and that the patterns and number of cycles of mastication affected the wear progression of enamel.


Assuntos
Porcelana Dentária , Zircônio , Animais , Bovinos , Esmalte Dentário , Mastigação , Teste de Materiais , Propriedades de Superfície , Zircônio/efeitos adversos
5.
Biomed Res Int ; 2021: 5581435, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34307657

RESUMO

OBJECTIVE: The introduction of CAD/CAM and the development of zirconia-based restorations have allowed clinicians to use less expensive materials and faster manufacturing procedures. The purpose of the study was to analyze the differences, in terms of mechanical and biological complication, in multiunit zirconia fixed dental prosthesis (FPDs) on posterior implants produced using a digital workflow. Method and Materials. This study was a retrospective investigation, and patients treated with screw-retained monolithic or partial veneer FPDs on dental implants were selected. Periapical radiographs were taken at baseline and at the 3-year follow-up. Complications were recorded and classified as technical and biological ones. RESULTS: The study population included 25 patients. The occlusal and interproximal corrections were not clinically significant. In the study sample, the survival rate and success rate of the FPDs after 3 years were 100% and 96%, respectively. One implant failed immediately after placement. CONCLUSION: Monolithic zirconia FPDs and partial veneer FPDs showed a 100% survival rate, presenting an interesting alternative to metal ceramic restorations. The partial veneer FPDs had a higher technical complication rate than the monolithic FPDs; however, no statistically significant difference was found.


Assuntos
Parafusos Ósseos/efeitos adversos , Desenho Assistido por Computador , Implantes Dentários , Facetas Dentárias , Prótese Parcial Fixa , Zircônio/efeitos adversos , Estudos Transversais , Estética , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fluxo de Trabalho
6.
ScientificWorldJournal ; 2021: 5540738, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113220

RESUMO

INTRODUCTION: Prosthetic dentistry has shifted toward prevention of caries occurrence surrounding restorative margin through the anti-demineralization process. This study examines the ability of nanohydroxyapatite (NHA) gel and Clinpro (CP) on enhancing resistance to demineralization of enamel and cementum at margin of restoration. MATERIALS AND METHODS: Thirty extracted mandibular third molars were segregated at 1 mm above and below cementoenamel junction (CEJ) to separate CEJ portions and substituted with zirconia disks by bonding to crown and root portions with resin adhesive. The enamel and cementum area of 4 × 4 mm2 neighboring zirconia was applied with either NHA or CP, while one group was left no treatment (NT) before demineralized with carbopal. Vickers hardness (VHN) of enamel and cementum was evaluated before material application (B M), after material application (A M), and after demineralization (A D). Analysis of variance (ANOVA) and post hoc multiple comparisons were used to justify for the significant difference (α = 0.05). Scanning electron microscopy (SEM) and X-ray diffraction (XRD) were determined for surface evaluations. RESULTS: The mean ± SD of VHN for B M, A M, and A D for enamel and cementum was 393.24 ± 26.27, 392.89 ± 17.22, 155.00 ± 5.68 and 69.89 ± 4.59, 66.28 ± 3.61, 18.13 ± 0.54 for NT groups, respectively, 390.10 ± 17.69, 406.77 ± 12.86, 181.55 ± 7.99 and 56.01 ± 9.26, 62.71 ± 6.15, 19.09 ± 1.16 for NHA groups, respectively, and 387.90 ± 18.07, 405.91 ± 9.83, 188.95 ± 7.43 and 54.68 ± 7.30, 61.81 ± 4.30, 19.22 ± 1.25 for CP groups, respectively. ANOVA indicated a significant increase in anti-demineralization of enamel and cementum upon application of NHA or CP (p < 0.05). Multiple comparisons indicated the capability in inducing surface strengthening to resist demineralization for enamel and cementum of NHA which was comparable to CP (p > 0.05) as evidenced by SEM and XRD data indicating NHA and CP deposition and crystallinity accumulation. CONCLUSION: NHA and CP were capable of enhancing anti-demineralization for enamel and cementum. The capability in resisting the demineralization process of NHA was comparable with CP. NHA was highly recommended for anti-demineralization for enamel and cementum surrounding restorative margin.


Assuntos
Cemento Dentário/patologia , Esmalte Dentário/patologia , Restauração Dentária Permanente/métodos , Durapatita/uso terapêutico , Nanoestruturas/uso terapêutico , Desmineralização do Dente/induzido quimicamente , Ítrio/uso terapêutico , Zircônio/uso terapêutico , Durapatita/efeitos adversos , Humanos , Microscopia Eletrônica de Varredura , Nanoestruturas/efeitos adversos , Ítrio/efeitos adversos , Zircônio/efeitos adversos
7.
Biomed Res Int ; 2020: 8821068, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33134389

RESUMO

OBJECTIVE: Long-term clinical data on the success and complication rates of monolithic or minimally veneered zirconia implant-supported restorations are lacking. Hence, the purpose of this retrospective clinical study was to analyze the complications of monolithic or partially veneered zirconia implant-supported restorations up to 5 years follow-up. Material and Methods. Single crowns, bridges, and full-arch rehabilitations were included. The selection process was achieved by reviewing data from the prosthetic laboratory and excluding cases in which zirconium and full-ceramic coating restorations were used. A total of 154 restorations were included (82 monolithic and 72 with buccal ceramic stratification). All the complications encountered, and the solutions applied, were explained. RESULTS: A total of 93 restorative units had a follow-up of between 24 and 60 months, and 61 restoration units had a follow-up of between 12 and 24 months. A total of 7 complications were encountered (14.58% of cases; 95.45% per prosthetic unit). The technical complication rate was 2.08% (one case of minor chipping in one prosthetic unit); regarding the mechanical complications, four decementations (8.33% of the cases) and two screw loosening (4.17% of the cases) were encountered. CONCLUSIONS: Considering the limitations of this study, it can be concluded that monolithic or partially veneered zirconia implant-supported restorations have a good clinical behavior during a follow-up period of up to 5 years.


Assuntos
Implantes Dentários/efeitos adversos , Materiais Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/efeitos adversos , Restauração Dentária Permanente/métodos , Zircônio/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Dentária Fixada por Implante/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-33093772

RESUMO

BACKGROUND: Forms of interstitial pneumonia secondary to exposure to an air-contaminant are varied and so far, insufficiently described. OBJECTIVES/METHODS: We report here a case of a 57-year-old patient managed in our department for the exploration of MRC grade 2 dyspnoea and interstitial pneumonia. He mentioned multiple occupational and domestic exposures such as hens' excrements, asbestos and metal particles; he also had a previous history of smoking. RESULTS: High-resolution computed tomography showed ground glass opacities predominating in posterior territories and surrounding cystic lesions or emphysematous destruction. The entire etiological assessment revealed only macrophagic alveolitis with giant multinucleated cells on the bronchoalveolar lavage. A surgical lung biopsy allowed us to refine the diagnosis with evidence of desquamative interstitial pneumonia and pulmonary granulomatosis. Finally, the analysis of the mineral particles in the biopsy revealed abnormally high rates of Zirconium and Aluminium. We were therefore able to conclude to a desquamative interstitial pneumonia associated with pulmonary granulomatosis linked to metal exposure (Aluminium and Zirconium). The clinical, functional and radiological evolution was favorable after a systemic corticosteroid treatment with progressive decay over one year. CONCLUSION: This presentation reports the first case to our knowledge of desquamative interstitial pneumonitis related to exposure to Zirconium and the third one in the context of Aluminium exposure. The detailed analysis of the mineral particles present on the surgical lung biopsy allows for the identification of the relevant particle to refine the etiological diagnosis, to guide the therapeutic management and to give access to recognition as an occupational disease. (Sarcoidosis Vasc Diffuse Lung Dis 2020; 37 (1): 79-84).


Assuntos
Alumínio/efeitos adversos , Granuloma do Sistema Respiratório/induzido quimicamente , Exposição por Inalação/efeitos adversos , Doenças Pulmonares Intersticiais/induzido quimicamente , Pulmão/efeitos dos fármacos , Zircônio/efeitos adversos , Corticosteroides/administração & dosagem , Alumínio/análise , Biópsia , Granuloma do Sistema Respiratório/diagnóstico , Granuloma do Sistema Respiratório/tratamento farmacológico , Granuloma do Sistema Respiratório/metabolismo , Humanos , Pulmão/química , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/metabolismo , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Zircônio/análise
9.
Neurochem Int ; 138: 104755, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32422323

RESUMO

Increasing evidence from toxicological and epidemiological studies indicates that the brain is an important target for ambient (ultrafine) particles. Disturbance of redox-homeostasis and inflammation in the brain are proposed as possible mechanisms that can contribute to neurotoxic and neurodegenerative effects. Whether and how engineered nanoparticles (NPs) may cause neurotoxicity and promote neurodegenerative diseases such as Alzheimer's disease (AD) is largely unstudied. We have assessed the neurological effects of subacute inhalation exposures (4 mg/m3 for 3 h/day, 5 days/week for 4 weeks) to cerium dioxide (CeO2) NPs doped with different amounts of zirconium (Zr, 0%, 27% and 78%), to address the influence of particle redox-activity in the 5xFAD transgenic mouse model of AD. Four weeks post-exposure, effects on behaviour were evaluated and brain tissues were analysed for amyloid-ß plaque formation and reactive microglia (Iba-1 staining). Behaviour was also evaluated in concurrently exposed non-transgenic C57BL/6J littermates, as well as in Western diet-fed apolipoprotein E-deficient (ApoE-/-) mice as a model of vascular disease. Markers of inflammation and oxidative stress were evaluated in brain cortex. The brains of the NP-exposed 5xFAD mice revealed no accelerated amyloid-ß plaque formation. No significant treatment-related behaviour impairments were observed in the healthy C57BL/6J mice. In the 5xFAD and ApoE-/- models, the NP inhalation exposures did not affect the alternation score in the X-maze indicating absence of spatial working memory deficits. However, following inhalation exposure to the 78% Zr-doped CeO2 NPs changes in forced motor performance (string suspension) and exploratory motor activity (X-maze) were observed in ApoE-/- and 5xFAD mice, respectively. Exposure to the 78% doped NPs also caused increased cortical expression of glial fibrillary acidic protein (GFAP) in the C57BL/6J mice. No significant treatment-related changes neuroinflammation and oxidative stress were observed in the 5xFAD and ApoE-/- mice. Our study findings reveal that subacute inhalation exposure to CeO2 NPs does not accelerate the AD-like phenotype of the 5xFAD model. Further investigation is warranted to unravel whether the redox-activity dependent effects on motor activity as observed in the mouse models of AD and vascular disease result from specific neurotoxic effects of these NPs.


Assuntos
Doença de Alzheimer/patologia , Cério/administração & dosagem , Exposição por Inalação , Atividade Motora/efeitos dos fármacos , Nanopartículas/administração & dosagem , Doenças Vasculares/patologia , Zircônio/administração & dosagem , Doença de Alzheimer/induzido quimicamente , Doença de Alzheimer/psicologia , Animais , Cério/efeitos adversos , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Atividade Motora/fisiologia , Nanopartículas/efeitos adversos , Doenças Vasculares/induzido quimicamente , Doenças Vasculares/psicologia , Zircônio/efeitos adversos
10.
Int J Mol Sci ; 20(10)2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-31137758

RESUMO

Although positron emission tomography (PET) imaging with 18-Fluorodeoxyglucose (18F-FDG) is a promising technique in multiple myeloma (MM), the development of other radiopharmaceuticals seems relevant. CD138 is currently used as a standard marker for the identification of myeloma cells and could be used in phenotype tumor imaging. In this study, we used an anti-CD138 murine antibody (9E7.4) radiolabeled with copper-64 (64Cu) or zirconium-89 (89Zr) and compared them in a syngeneic mouse model to select the optimal tracers for MM PET imaging. Then, 9E7.4 was conjugated to TE2A-benzyl isothiocyanate (TE2A) and desferrioxamine (DFO) chelators for 64Cu and 89Zr labeling, respectively. 64Cu-TE2A-9E7.4 and 89Zr-DFO-9E7.4 antibodies were evaluated by PET imaging and biodistribution studies in C57BL/KaLwRij mice bearing either 5T33-MM subcutaneous tumors or bone lesions and were compared to 18F-FDG-PET imaging. In biodistribution and PET studies, 64Cu-TE2A-9E7.4 and 89Zr-DFO-9E7.4 displayed comparable good tumor uptake of subcutaneous tumors. On the bone lesions, PET imaging with 64Cu-TE2A-9E7.4 and 89Zr-DFO-9E7.4 showed higher uptake than with 18F-FDG-PET. Comparison of both 9E7.4 conjugates revealed higher nonspecific bone uptakes of 89Zr-DFO-9E7.4 than 64Cu-TE2A-9E7.4. Because of free 89Zr's tropism for bone when using 89Zr-anti-CD138, 64Cu-anti-CD138 antibody had the most optimal tumor-to-nontarget tissue ratios for translation into humans as a specific new imaging radiopharmaceutical agent in MM.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Radioisótopos de Cobre/farmacocinética , Mieloma Múltiplo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Sindecana-1/imunologia , Zircônio/farmacocinética , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Neoplasias Ósseas/secundário , Linhagem Celular , Linhagem Celular Tumoral , Radioisótopos de Cobre/efeitos adversos , Radioisótopos de Cobre/química , Feminino , Fluordesoxiglucose F18/farmacocinética , Camundongos , Camundongos Endogâmicos C57BL , Mieloma Múltiplo/patologia , Radioisótopos/efeitos adversos , Radioisótopos/química , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/química , Sindecana-1/química , Distribuição Tecidual , Zircônio/efeitos adversos , Zircônio/química
11.
J Dent ; 88: 103115, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30986515

RESUMO

OBJECTIVES: To compare the survival rate of abutments, marginal bone loss and peri-implant soft tissue discoloration among implant-supported single crowns with different abutment materials. DATA: Randomized controlled trials (RCTs), controlled clinical trials, and cohort studies of implant-supported single crowns with different dental abutment materials. SOURCES: A systematic search was conducted by an electronic search in 6 databases without restrictions on September 16, 2018, complemented by a manual search. "Grey" literatures were also searched. STUDY SELECTION: Of 3417 studies initially retrieved, thirteen were eligible for inclusion. After studies selected and data extraction, pair-wise and network meta-analyses were performed to analyze the survival rate of the abutment, the marginal bone loss and the soft tissue discoloration. The risk of bias was assessed based on the Cochrane guidelines, Newcastle-Ottawa scale, and funnel plots. Statistical heterogeneity, inconsistencies, and cumulative ranking were also evaluated. RESULTS: Fourteen RCTs and nine non-RCTs were included. No significant differences was detected among titanium (Ti), zirconia (Zr), gold (Au), and alumina (Al) abutments in terms of survival rate (excluding Al < Ti (P < 0.05), marginal bone loss (excluding Zr < Ti (P < 0.05) and Au > Zr (P < 0.05)), or discoloration of peri-implant soft tissue. Additionally, Ti abutment had the highest cumulative ranking of survival rate (97.9%); Al abutment had the lowest marginal bone loss (81.4%) and Zr abutment had the least discoloration of peri-implant soft tissue (84.8%). CONCLUSIONS: Ti abutment has a comparable survival rate with Zr, but better than Al. In addition, Zr abutment has a better effect in maintaining the marginal bone level, compared with Au and Ti. However, there was no difference in the discoloration of peri-implant soft tissue among Au, Ti, and Zr abutment. CLINICAL SIGNIFICANCE: Based on the results of our network meta-analysis, Zr might be a recommended abutment material considering the clinical efficacy of implant-supported single crowns.


Assuntos
Coroas , Dente Suporte/efeitos adversos , Implantes Dentários para Um Único Dente , Titânio/efeitos adversos , Zircônio/efeitos adversos , Cor , Projeto do Implante Dentário-Pivô , Estética , Humanos , Metanálise em Rede , Taxa de Sobrevida
12.
J Prosthet Dent ; 120(3): 327-330, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29627215

RESUMO

Two zirconia-based 4-unit restorations intended for the same patient fractured during the veneering process even though the prolonged cooling protocol recommended by the manufacturers was used. Fractographic analyses revealed that both restorations fractured as a result of thermal shock, but at different times during production. Further investigation is necessary to optimize the firing protocols for large zirconia-based restorations and avoid fracture due to thermal shock.


Assuntos
Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Facetas Dentárias/efeitos adversos , Temperatura Alta/efeitos adversos , Zircônio/efeitos adversos , Adulto , Implantes Dentários/efeitos adversos , Humanos , Masculino , Zircônio/uso terapêutico
13.
Oper Dent ; 43(5): 482-487, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29513640

RESUMO

OBJECTIVES: To evaluate the clinical behavior of one-piece complete-coverage crowns and fixed partial dentures (FPDs) on teeth with vertical preparation without finish line biologically oriented preparation technique (BOPT). METHODS AND MATERIALS: This prospective study included 52 patients requiring treatment with restorations in the esthetic region: 74 crowns and 27 FPDs. The sample included a total of 149 teeth that were prepared vertically without finish line. The sample was divided into two groups: one-piece crowns and FPDs, all with zirconia cores, feldspathic ceramic veneer, and a 0.5-mm prosthetic finish line of zirconia. All procedures were carried out at the University of Valencia from 2013 to 2014. The following parameters were evaluated over a two-year follow-up: oral hygiene, periodontal state, gingival thickening, gingival margin stability, the presence of complications, and restoration survival rate. Patient satisfaction with treatment was assessed by means of a visual analogue scale (VAS). RESULTS: Two years after treatment, 80.5% of treated teeth remained free of gingival inflammation and bleeding. Mean gingival thickening was 0.41 ± 0.28 mm for one-piece crowns and 0.38 ± 0.36 mm for FPDs. Gingival margin stability was 100%, but 2% of the sample presented biological complications. The VAS patient satisfaction scores were eight out of a maximum score of 10. CONCLUSIONS: Two years after treatment, vertical preparation without finish line produces gingival thickening, margin stability, and optimal esthetics. Neither crowns nor FPDs presented any mechanical complications.


Assuntos
Coroas , Restauração Dentária Permanente/métodos , Doenças da Gengiva/etiologia , Zircônio/uso terapêutico , Adolescente , Adulto , Idoso , Cerâmica/efeitos adversos , Cerâmica/uso terapêutico , Coroas/efeitos adversos , Restauração Dentária Permanente/efeitos adversos , Estética Dentária , Feminino , Seguimentos , Gengiva/efeitos dos fármacos , Doenças da Gengiva/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Adulto Jovem , Zircônio/efeitos adversos
14.
J Dent ; 72: 14-20, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29452242

RESUMO

OBJECTIVES: The aim of this study was to assess the clinical outcomes and patient satisfaction with monolithic zirconia crowns in patients with severe tooth wear (≥1/3 of the tooth crown) in the aesthetic zone. METHODS: The historical prospective study sample consisted of 13 patients previously treated with a total of 84 monolithic zirconia crowns. The patients had been treated in a private clinic in Bergen, Norway, in the period 2012 to 2014. All patients were men, aged 35-67 years (mean age 56.3 years) and had been in need of prosthetic rehabilitation because of severe tooth wear in the aesthetic zone. Technical complications as well as biologic findings were registered when the crowns had been in function one to three years (mean 20 months). The patients completed a self-administered questionnaire regarding satisfaction with aesthetic and function. RESULTS: No biological complications were registered in 79 of the crowns (94%), and technical complications were registered in only two patients. All patients were satisfied with the aesthetic and function of the monolithic zirconia crowns and would choose the same treatment modality if they were to be treated again. CONCLUSIONS: Within the limitations of this study, we conclude that the rate of clinical complications was low and that the patients were satisfied with the aesthetic as well as the function of the monolithic zirconia crowns. CLINICAL SIGNIFICANCE: Monolithic zirconia crowns may provide a valid treatment modality in the aesthetic zone in patients with severe tooth wear.


Assuntos
Bruxismo/complicações , Coroas/efeitos adversos , Materiais Dentários/efeitos adversos , Desgaste de Restauração Dentária , Estética Dentária/psicologia , Desgaste dos Dentes/etiologia , Zircônio/efeitos adversos , Adulto , Idoso , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Humanos , Masculino , Pessoa de Meia-Idade , Noruega , Satisfação do Paciente , Estudos Prospectivos , Propriedades de Superfície , Inquéritos e Questionários , Desgaste dos Dentes/diagnóstico por imagem , Desgaste dos Dentes/reabilitação , Resultado do Tratamento
15.
J Dent ; 70: 110-117, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29371043

RESUMO

OBJECTIVES: The implant abutments, which had their own colour, might cause the discoloration of peri-implant mucosa. We aimed to appraise trails comparing the discoloration of peri-implant soft tissue around zirconia and titanium or golden abutments, the tints of which were vastly different. DATA: We included randomized controlled trials (RCTs), controlled clinical trials (CCTs), cohort studies with patients rehabilitated with zirconia, titanium or golden implant abutments, quantitatively comparing the discoloration of peri-implant soft tissue according to CIE-Lab colour scale. SOURCES: A systematic search was conducted in PubMed, EMBASE, CDSR, and CENTRAL databases without any restriction on September 23, 2017. "Grey" literatures were also searched. A manual search was carried out as well. STUDY SELECTION: Of 584 articles initially retrieved, eight were eligible for inclusion. After data extraction, meta-analyses with mean differences (MDs) and their 95% confidence intervals (CIs) were employed. Moreover, the risk of bias within or across studies was assessed by Cochrane Collaboration's tool for assessing risk, the Newcastle-Ottawa scale, funnel plots, or Egger's test. RESULTS: Four RCTs and four cohort studies were included. Soft-tissue discoloration around zirconia abutments was significantly less likely compared to that around titanium abutments (MD = -1.84; 95% CI = -3.62 to -0.07; P = 0.04 < 0.05) or golden abutments (MD = -0.90; 95% CI = -1.60 to -0.20; P = 0.01 < 0.05). CONCLUSIONS: Zirconia abutments with white tint compared to grey titanium or golden abutments seem to restore a more appropriate colour match between peri-implant mucosa and natural teeth. CLINICAL SIGNIFICANCE: Based on the present evidence, the "nature-like" zirconia abutments should be applied more often in the clinic. PROSPERO REGISTRATION NUMBER: CRD42017075930.


Assuntos
Cor , Dente Suporte/efeitos adversos , Implantes Dentários/efeitos adversos , Gengiva/patologia , Zircônio/efeitos adversos , Bases de Dados Factuais , Implantação Dentária Endóssea , Materiais Dentários/efeitos adversos , Planejamento de Prótese Dentária , Estética Dentária , Ligas de Ouro/efeitos adversos , Humanos , Titânio/efeitos adversos
16.
J Bone Joint Surg Am ; 100(2): 115-123, 2018 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-29342061

RESUMO

BACKGROUND: The effect of alternative bearing materials on the risk of revision due to infection after total knee replacement remains uncertain. By reducing the immunomodulating polyethylene wear-particle burden and with different substrate bacterial adhesion properties, Oxinium oxidized zirconium and cross-linked polyethylene (XLPE) could alter infection risk. The purpose of the current study was to analyze the risk of revision for infection in 3 comparisons of bearing combinations. METHODS: To evaluate the risk of revision for infection with XLPE, cobalt-chromium (CoCr) on XLPE was compared with CoCr on non-cross-linked polyethylene (NXLPE). To evaluate Oxinium, Oxinium-NXLPE was compared with CoCr-NXLPE, and to evaluate the possibility of an additional beneficial effect of Oxinium on XLPE, Oxinium-XLPE was compared with CoCr-XLPE. The cumulative percent revision (CPR) and hazard ratio (HR) for revision for infection in primary total knee replacement for osteoarthritis were determined from registry data from September 1, 1999, to December 31, 2015. Revisions within 6 months following the primary surgery were censored from the analysis, while procedures with posterior stabilized or fully stabilized total knee replacements as well as prostheses with a known higher risk of revision were excluded. Analyses were stratified by age, sex, and fixation type. RESULTS: Of the 326,603 included primary total knee replacements, 1,511 (0.46%) were revised for infection. The risk of revision for infection was lower for CoCr-XLPE compared with CoCr-NXLPE (HR = 0.74; 95% confidence interval [CI] = 0.65 to 0.84; p < 0.001). This effect was apparent for both male and female patients overall, all fixation types, antibiotic cement use, those <65 years of age, and male patients ≥65 years of age. However, for female patients ≥65 years of age, there was no difference. Overall, Oxinium-NXLPE had the same revision risk as CoCr-NXLPE regardless of fixation; however, for cemented fixation, subanalysis showed a lower risk for Oxinium-NXLPE compared with CoCr-NXLPE (HR = 0.69; 95% CI = 0.51 to 0.94; p = 0.018). Oxinium-XLPE had the same revision risk for infection as CoCr-XLPE overall, among male patients, and when cemented fixation had been used. CONCLUSIONS: In this registry analysis, CoCr-XLPE had a 26% lower risk of revision for infection than CoCr-NXLPE, suggesting a reduction of wear particle-induced immunomodulation with XLPE. Oxinium-XLPE had the same risk as CoCr-XLPE. Overall, Oxinium did not reduce the infection risk. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Infecção da Ferida Cirúrgica/cirurgia , Adulto , Idoso , Austrália , Ligas de Cromo/efeitos adversos , Ligas de Cromo/química , Reagentes de Ligações Cruzadas/efeitos adversos , Reagentes de Ligações Cruzadas/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Polietileno/química , Sistema de Registros , Fatores de Risco , Propriedades de Superfície , Zircônio/efeitos adversos , Zircônio/química
17.
Int Orthop ; 42(1): 65-70, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28725970

RESUMO

INTRODUCTION: Literature on the potential release of trace elements following implantation of Zirconia-platelet toughened alumina (ZPTA) ceramic components is scant. The present study therefore analysed the in vitro and in vivo potential release of ions from ZPTA bearings. MATERIAL AND METHODS: An in vitro and in vivo study was conducted. The in vitro study compared leaching in bovine serum from two groups: ZPTA ceramic heads and Co-28Cr-6Mo alloy heads, both 28-mm diameter. A third group without implant served as reference group. An in vivo clinical study compared trace elements in the whole blood of patients with 36-mm diameter ZPTA ceramic-on-ceramic articulation after three and 12 months. A cohort of subjects without any prosthesis was used as control group. The release of ions was determined by high resolution-inductively coupled plasma-mass spectrometry. RESULTS: In the in vitro experiment, significant differences (p ≤ 0.01) in trace element release for chromium, cobalt and molybdenum were found, with increased levels of ion release in the Co-28Cr-6Mo metal group. The very low detection limit for yttrium allowed detection of a small yttrium release from the ZPTA heads, which was not confirmed by the in vivo study. No significant difference between the groups was found for strontium, aluminium, and zirconium. In the in vivo study, no relevant differences in ion levels between the reference group without any implant and the study group were found at the three and 12-month follow-up. CONCLUSION: This study supports that ZPTA ceramic articulation components are safe in terms of ion release, and may be an excellent alternative to bearings based on Co-28Cr-6Mo alloys.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Desenho de Prótese/métodos , Oligoelementos/sangue , Zircônio/efeitos adversos , Adulto , Idoso , Ligas/efeitos adversos , Animais , Artroplastia de Quadril/instrumentação , Bovinos , Cerâmica/efeitos adversos , Feminino , Humanos , Íons , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Desenho de Prótese/efeitos adversos
18.
J Prosthet Dent ; 119(2): 286-291, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28533011

RESUMO

STATEMENT OF PROBLEM: Studies of composite resin repairs of yttrium-tetragonal zirconia polycrystal (Y-TZP) are usually performed in its tetragonal phase, but it may be partially transformed into a monoclinic phase in a clinical fracture. PURPOSE: The purpose of this in vitro study was to evaluate the effect of airborne-particle abrasion (APA) and a bonding agent on the shear bond strength (SBS) between a composite resin and hydrothermally aged Y-TZP. MATERIAL AND METHODS: Specimens (7.0×7.0×1.7 mm, N=112) of Y-TZP Lava were obtained, and 50% were aged in an autoclave at 134°C at 300 kPa for 8 hours. The surfaces were treated with APA 50-µm Al2O3 particles (ALU) or Rocatec Soft (30 µm) (ROC) followed by Clearfil SE Bond Primer (10-methacryloyloxydecyl dihydrogen phosphate [10-MDP]) plus Clearfil porcelain bond activator (3-methacryloxypropyl-trimethoxy silane [3-MPS]) (CLE) or RelyX Ceramic Primer plus a layer of RelyX U100 adhesive-resin cement (REL). Composite resin cylinders were built on the Y-TZP treated surfaces. After thermocycling (6000 cycles, 5°C and 55°C, 30-second dwell time), an SBS test was carried out (n=14). Data were analyzed by 3-way ANOVA and the Tukey honest significant differences test (α=.05). The failure mode was analyzed. RESULTS: The 3-way ANOVA was not significant for aging (P>.05), but the APA (P<.001), bonding agent (P<.001), and their interaction (P<.001) were significant. APA with ALU or ROC did not influence the SBS of the groups bonded with CLE, but the REL APA with ROC provided higher SBS. The failure mode was adhesive for all specimens. CONCLUSIONS: Adhesion was not different on monoclinic partially transformed Y-TZP. The APA with ROC followed by REL was the most effective treatment for repairing Y-TZP.


Assuntos
Resinas Compostas/uso terapêutico , Reparação em Prótese Dentária/métodos , Ítrio , Zircônio , Colagem Dentária/métodos , Corrosão Dentária/métodos , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Ítrio/efeitos adversos , Ítrio/uso terapêutico , Zircônio/efeitos adversos , Zircônio/uso terapêutico
19.
Clin Implant Dent Relat Res ; 20(2): 160-169, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29181880

RESUMO

BACKGROUND: Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials. PURPOSE: To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, and gold alloy, over an 8-week healing period. MATERIALS AND METHODS: Fifteen edentulous sites were treated with implants. Eight weeks later, peri-implant tissue was harvested and processed using a nonseparation resin embedded technique. The tissue attachment characteristics were assessed at clinical stages using the gingival index (GI) score, surgical stage (surgical score), and histological stage (histological attachment percentage). Additionally, the inflammatory responses were evaluated using inflammatory extent and inflammatory cellularity grades. Nonparametrical statistics were used to describe the GI and surgical scores, and analytical statistics were used to analyze the histological attachment percentages as well as the inflammatory extent and cellularity grades amongst the 3 groups. RESULTS: There were no statistically significant differences among the groups for GI score (P = .071) and surgical score (P = .262). Titanium and zirconia exhibited nearly similar mean histological attachment percentages while gold alloy had a significantly lower percentage (P = .004). For the inflammatory extent and cellularity grades, the odds of being one grade higher for gold alloy abutment was 5.18 and 17.8 times that of titanium abutment, respectively. However, for the zirconia abutment, the odds were 0.87 and 7.5 times higher than the titanium group. CONCLUSIONS: The tissue around the gold alloy abutments resulted in worse attachment conditions compared with the titanium and zirconia abutments. Inflammation tended to be higher in the tissue around the gold alloy abutments than the titanium and zirconia abutments.


Assuntos
Dente Suporte/efeitos adversos , Gengivite/induzido quimicamente , Ligas de Ouro/efeitos adversos , Titânio/efeitos adversos , Zircônio/efeitos adversos , Biópsia , Projeto do Implante Dentário-Pivô , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Osseointegração , Índice Periodontal , Projetos Piloto
20.
J Dent ; 68: 19-27, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29042241

RESUMO

OBJECTIVES: To test the hypothesis that there is no difference in the in vivo maximum wear of enamel opposing monolithic zirconia crowns, enamel opposing porcelain fused to metal crowns and enamel opposing enamel. METHODS: Thirty patients needing single crowns were randomized to receive either a monolithic zirconia or metal-ceramic crown. Two non-restored opposing teeth in the same quadrants were identified to serve as enamel controls. After cementation, quadrants were scanned for baseline data. Polyvinylsiloxane impressions were obtained and poured in white stone. Patients were recalled at six-months and one-year for re-impression. Stone models were scanned using a tabletop laserscanner to determine maximum wear. Statistical analysis was performed using Mann-Whitney U to determine any significant differences between the wear of enamel against zirconia and metal-ceramic crowns. RESULTS: Sixteen zirconia and 14 metal-ceramic crowns were delivered. There were no statistical differences in mean wear of crown types (p=0.165); enamel antagonists (p=0.235) and enamel controls (p=0.843) after one year. CONCLUSION: Monolithic zirconia exhibited comparable wear of enamel compared with metal-ceramic crowns and control enamel after one year. SIGNIFICANCE: This study is clinically significant because the use of polished monolithic zirconia demonstrated comparable wear of opposing enamel to metal-ceramic and enamel antagonists.


Assuntos
Coroas , Materiais Dentários/efeitos adversos , Porcelana Dentária/efeitos adversos , Desgaste de Restauração Dentária , Desgaste dos Dentes , Zircônio/efeitos adversos , Cimentação , Esmalte Dentário , Feminino , Florida , Humanos , Masculino , Teste de Materiais , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA